Click
to return to CAL-RF Listing
CAL-RF
Design Guide
Low Loss Semi-Rigid
Coaxial Cable
Low-Loss
EZBend II Semi-Rigid cable from Cal-RF is manufactured
with an expanded PTFE dielectric to deliver low attenuation
and high power over a broad frequency range. Increased
phase stability and higher operating temperatures
provide excellent electical characteristics for equipment
designers and manufacturers. In addition, the soft
annealed copper or aluminum outer conductor allows
easy bending by hand with no springback. Our skilled
technicians can fabricate cable assemblies or delay
lines with a wide range of connectors specially matched
to this high performance cable. Where space or performance
are critical, the .141 Low Loss cable has comparable
attenuation values to the standard .250 cable at 20
GHz. Low Loss EZBend II is a registered product name
manufactured by Haverhill Cable and Manufacturing
Corporation.
|
| |
|
| Electrical
Specifications, Low Loss Semi-Rigid Cable |
| L25 |
6 |
20 |
34 |
2800 |
700 |
400 |
50
± 1.0 |
25.5 |
87.8 |
20 |
7.5 |
3.0 |
 |
8 |
| L25A |
6 |
20 |
34 |
2800 |
700 |
400 |
50
± 0.5 |
25.5 |
87.8 |
20 |
7.5 |
3.0 |
 |
8 |
| L14C |
7.5 |
28 |
42 |
900 |
200 |
100 |
50
± 0.5 |
26.2 |
86.0 |
40 |
5.0 |
1. |
 |
9 |
| L14A |
7.5 |
32 |
47.4 |
900 |
200 |
100 |
50
± 1.0 |
26.2 |
86.0 |
40 |
5.0 |
1.2 |
 |
9 |
| L08C |
14 |
53 |
82 |
260 |
70 |
40 |
50
± 1.0 |
26.6 |
87.7 |
60 |
5.0 |
1.5 |
 |
10 |
| L08A |
14 |
53 |
82 |
260 |
70 |
40 |
50
± 1.0 |
26.6 |
87.7 |
60 |
4.0 |
1.0 |
 |
10 |
| L04C |
35 |
111 |
159 |
60 |
15 |
10 |
50
± 2.0 |
32.0 |
76.1 |
118 |
2.0 |
1.5 |
 |
11 |
| L04A |
32 |
111 |
159 |
60 |
15 |
10 |
50
± 2.0 |
23.9 |
77.8 |
120 |
2.0 |
1.0 |
 |
11 |
| Mechanical
Specifications, Low Loss Semi-Rigid Cable |
| L25C |
50
± 1.5 |
.2500 |
Cu |
.209 |
.0808 |
SC |
1.00 |
25 |
-40
TO 200 |
 |
8 |
| L25A |
50
± 0.5 |
.2500 |
Al |
.209 |
.0808 |
SC |
1.00 |
51 |
-40
TO 200 |
 |
8 |
| L14C |
50
± 0.5 |
.141 |
Cu |
.120 |
.0455 |
SC |
.625 |
27 |
-65
TO 250 |
 |
9 |
| L14A |
50
± 1.0 |
.141 |
Al |
.120 |
.0455 |
SC |
.625 |
13.5 |
-65
TO 250 |
 |
9 |
| L08C |
50
± 1.0 |
.0865 |
Cu |
.066 |
.0255 |
SC |
.125 |
13.3 |
-65
TO 250 |
 |
10 |
| L08A |
50
± 1.0 |
.0865 |
Al |
.066 |
.0255 |
SC |
.125 |
6.6 |
-65
TO 250 |
 |
10 |
| L04C |
50
± 2.0 |
.0470 |
Cu |
.038 |
.0127 |
SC |
.125 |
4. |
-55
TO 250 |
 |
11 |
| L04A |
50
± 2.0 |
.0470 |
Al |
.038 |
.0130 |
SC |
.050 |
3.8 |
-55
TO 250 |
 |
11 |
| Key
to Abbreviations |
| Conductor
Materials |
| AL |
Tin-plated
Aluminum |
| CU |
Copper |
| CW |
Copper
plated steel (Copperweld) |
| SC |
Silver-plated
copper |
| SCW |
Silver-plated
Copperweld |
| SSC |
Stranded
silver-plated copper |
| TC |
Tinned
copper |
| Dielectric/Jacket
Material |
| Comp. |
Composite
Shield |
| FEP |
Florinated
Ethylene Polypropylene |
| FGB |
Fiberglass
Braid |
| FTPTFE |
Foamed-tape
Teflon |
| PE |
PolyEthylene |
| PTFE |
Teflon
PolyTetraFluorEthylene |
| PVC |
PloyVinyl
Choloride |
| Electric
Terms |
| DWV |
Dielectric
Withstanding Voltage |
| Corona
Extinction |
Time
in minutes @ voltage per MIC-C-17 |
| FEP
and PTFE are registered trademarks of the DuPont Corp. |
CONTACT
INFORMATION
Tim-Co
Component Sales/ California RF Components 3910-A Royal Ave
Simi Valley, Ca 93063
|
|
Phone
- Tim-Co:
or
Phone - CAL-RF:
Fax: |
(805) 582-1777
(800)
238-4626
(805) 582-1444 |
E-MAILS
Contact
Our Salesperson Directly At:
| Inside
Sales |
E-mail |
| |
|
| Danny
Soliz |

|
| Ron
Reichick |
|
| J.J.
Clarizio |
|
| Engineering |
|
|
Engineering |
acasanova@tim-co.com |
|
|
County
|
Engineering
Field Sales
|
Phone
|
|
LA
South and Orange
|
Joe
Casmero
|
714-598-9757
|
|
We
accept the following credit cards ...

|
|
~
Contact Tim-Co for Inventory Information ~
|
|